MATERIAL SAFETY DATA SHEET SAWYER’S PERMETHRIN TICK REPELLENT PUMP & SPRAY NON-AEROSOL PUMP CLOTHING TREATMENT ONLY DO NOT APPLY TO SKIN
TRADE NAME: SAWYER’S PERMETHRIN TICK REPELLENT PUMP & SPRAY
EPA ESTABLISHMENT NO: 67187-NY-1 or 54287-FL-1
Aromatic Petroleum Distillate, Xylene Range
Inert Ingredients (Proprietary mixture of solvents, surfactants, and preservatives)
*(3-phenoxyphenyl)methyl (+/-) cis/trans 3-(2,2-dichloroethenyl)-2,2-dimethyl cyclopropanecarboxylate. Cis/trans ratio: min. 35% (max. 40%) (+/-) cis and max. 65% (min. 60%) (+/-) trans.
Flash Point, (TCC), °F: >200 Autoignition Temperature, °F: NA Flammable Limits In Air, Volume %: Lower NE Upper NE Fire Extinguishing Materials: X Water Spray X Carbon Dioxide X Foam X Dry Chemical Other Special Firefighting Procedures: None
Unusual Fire and Explosion Hazards: None
Symptoms of Overexposure for Each Potential Route of Exposure: Inhaled: None
-------------------------------------------------------------------- Health Effects or Risk From Exposure: Acute: NE
-------------------------------------------------------------------- First Aid; Emergency Procedures: Eye Contact: Flush eyes with plenty of water. Call a physician if irritation persists. Skin Contact: Remove contaminated clothing and wash affected areas with soap and water. If Swallowed: Drink one or two glasses of water and induce vomiting by touching back of throat with finger. Repeat until vomit fluid is clear. Call a physician immediately. Do not induce vomiting or give anything by mouth to an unconscious person. If Inhaled: Remove affected person to fresh air. Apply artificial respiration, if indicated. -------------------------------------------------------------------- Suspected Cancer Agent?
X No: This product's ingredients are not found in the lists below. Yes: Federal OSHA NTP IARC Cal/OSHA
Stability: X Stable Unstable Conditions to Avoid: Do not store when Temperature exceeds 130°F. Incompatibility (materials to avoid): None Hazardous Decomposition Products (including combustion products): None Hazardous Polymerization: May Occur X Will Not Occur Conditions to Avoid: None
Spillage or Leakage Procedures; steps to be taken in case material is spilled or released; Faulty or leaking container: Keep people away. Open all windows and doors and ventilate area thoroughly. Allow to discharge safely, avoiding breathing vapors. Soak up residues with an absorbent material. Preparing Wastes for Disposal (container types, neutralization): Replace cap, wrap container in several layers of newspaper, and discard container in trash. Dispose of absorbents in trash. NOTE: Dispose of all Wastes in Accordance with Federal, State and Local Regulations.
Ventilation and Engineering Controls: None
Eye Protection (type): Safety glasses, goggles or face shield
Work Practices, Hygienic Practices: Follow Label Directions
Other Handling and Storage Requirements: Do not store where temperature falls below 32°F.
Labeling; Precautionary Statements: KEEP OUT OF REACH OF CHILDREN. Avoid contact with face, eyes, or skin. Avoid breathing vapors or spray mist. Harmful if swallowed. Wash thoroughly after handling and before eating or smoking. Do not use on humans. Do not retreat clothing within 2 weeks unless the clothing has been laundered between treatments. Other Precautions: CLOTHING TREATMENT ONLY. DO NOT APPLY TO SKIN.
TSCA (Toxic Substances Control Act) Regulations, 40 CFR 710: This product is a pesticide and is exempt from TSCA regulation. CERCLA and SARA Regulations (40 CFR 355, 370, and 372): This product does not contain any chemicals subject to the reporting requirements of SARA Section 313.
NA = Not Applicable NE = None (not) Established THE INFORMATION CONTAINED HEREIN IS BELIEVED TO BE ACCURATE WHETHER ORIGINATING WITH SAWYER PRODUCTS INCORPORATED OR NOT. SAWYER PRODUCTS INCORPORATED PROVIDES NO WARRANTY EITHER EXPRESS OR IMPLIED, AND ASSUMES NO RESPONSIBILITY FOR THE ACCURACY OR COMPLETENESS OF THE DATA. RECIPIENTS ARE ADVISED TO CONFIRM ANY DATA, IN ADVANCE OF NEED, THAT IT IS CURRENT, APPLICABLE, AND SUITABLE TO THEIR CIRCUMSTANCES.
Giles Scientific Inc. Specifications of the BIOMIC V3 System 1. BIOMIC V3 is of a high-resolution 1280 x 1024 pixel color digital image analysis system. 2. BIOMIC V3 contains a uniform non-breakable light source over and under the test sample, including darkfield and optional ultraviolet lighting. 3. BIOMIC V3 includes a built-in 15” touch-screen monitor to facil
NEWS RELEASE PUBLISHED STUDY SHOWS MORE PATIENTS SEE IMPROVEMENT IN OVERACTIVE BLADDER SYMPTOMS WITH URGENT® PC DEVICE COMPARED TO THOSE USING A DRUG 80% of Patients Treated with Urgent PC Reported Improvement Compared to 55% of Those Using an OAB Drug in a Study Published in September’s Journal of Urology MINNEAPOLIS, MN, September 3, 2009 – Uroplasty, Inc.