Overview
WS-DLXm measures process signals and transmits data to the base station. Sensing is done
using any available sensor that has 0 – 1 V DC output. This al ows connecting many commercial y
available sensors that monitor a wide variety of measurement parameters such as flow, level,
pressure etc. Sensor values are sent by the receiving base station to:
- WiSensys® PC software SensorGraph via a serial interface or to
- Wisensys® internet Websensys via TCP/IP or GPRS
- Or to a data logger, PLC, automation system via RS485/422
- Or in the case the base station is equipped with an analog output module the values
can be forwarded as 0 -10 V DC or 4-20 mA signals (max 4 outputs) to a data logger or
The intervals for sensing and transmission are set at instal ation time. Values can be changed
WS-DLXm has a unique identity and a network ID. Transmitted data is encrypted thereby avoiding
other wireless systems or receivers to receive the data. Optional y the fol owing values can be
Trip values are used to signal an alarm condition to the base station.
The sensor can local y store up to 10.000 measurements in non-volatile memory. This storage is
used when a connection to the base station is not available to ensure that measurements are not
lost. Whenever the sensor and base station are in range again, the data is transmitted to the base
The distance between sensor and base station can be up to 1000 meters in case of free line-of-
sight. Characteristic in-building range values are between 50 and 80 meters.
Sensor versions
Based on the power supply of the sensor we distinguish the fol owing situations:
- Order the WS-DLXm having a 3.6V Lithium battery. With default settings of sensing
and transmission intervals, the lifetime of the battery is 3 years.
- Power from the electrical grid is available; order the WS-DLXm-extp; the sensor
element is powered via this unit or via an own power supply
Features
• Ability to store 10.000 measurements; overwrites oldest data when ful
• Attractive ABS enclosure; other enclosures upon request
• Wal mounting possibilities included in enclosure
• Range: 1000m with free line-of-sight
• Easy to add sensors to operational system www.wisensys.com
Specification WS-DLXm; WS-DLXm-extp;
Function Sensor type Measurement range Measurement accuracy Measurement resolution Input impedance Overload protection Measurement interval (M)
Maximum 200 seconds, default 20 seconds. Samples per transmission (T)
From 1 to 10 samples, default 1. Alarm thresholds for base station Operating limits battery 1 AA 3.6V Lithium battery Externally powered 8 -24 V DC adapter for connection to the grid Battery life1
3 years with default settings for M and T
5 years with M=60 seconds and T=default Radio standard Frequency Dimensions2 battery 60(w) x 80(h) x 26(d) mm, excl. wal mount Externally powered 95(w) x 130(h) x 45(d) mm, excl. wal mount Configuration
Through WiSensys® PC software SensorGraph
Regulatory
R&TTE, CE (EMC and Low voltage directive)
1) For WS-DLXm battery life also depends on operating temperature.
Connection external power
(specified average and peak current is without
The specification is subject to change without notice.
WiSensys® is a registered trademark of Wireless Value.
The dental term "xerostomia" means dryness of the mouth due to a decreased function of the glands that produce saliva. It is the sensation of dryness It is experienced when saliva flow decreases by half of its normal flow It affects up to 10 million people in the UK It can lead to an increase in tooth decay, soreness & infections of the mouth It can be
Executive Office of Health and Human Services DEVAL L. PATRICK GOVERNOR TIMOTHY P. MURRAY LIEUTENANT GOVERNOR JUDYANN BIGBY, MD SECRETARY JOHN AUERBACH COMMISSIONER MEMORANDUM Jon Burstein , State EMS Medical Director April 9, 2010 (Update of memorandum dated November 19, 2007) EMT- Basics and Intermediates: Update of Assisted Albuterol Program for Trea