Master

(Formerly known as Nitocote EP901)
High chemical resistant protective lining
Nitocote EN901 is an Epoxy Novolac lining designed to provide Solid content
protection to concrete and steel structures in aggressive chemical conditions. The material is particularly suitable in wastewater treatment plants, desalination plants, food Specific gravity
processing plants, pump and paper mills, electric power plants, chemical manufacturing plants, fertiliser and insecticide plants and petroleum refineries.
Tack-free time
Nitocote EN901 may be used with or without Fosroc Anti-slip grains as a heavy-duty floor coating in applications such as Overcoating time
chemical processing and drum storage areas, loading docks and ramps. It may also be used in conjunction with glass Full cure
fibre cloth to increase the thickness of the system or to reinforce structures subjected to aggressive chemicals.
Tensile strength
Elongation
Flexural strength
Compressive strength :
Excellent chemical resistance in pH ranging from 1-14 Hardness
Abrasion resistance
(1 kg, H-22 Wheels)
Excellent adhesion to properly prepared concrete, mild Service temperature
The fully cured coating is resistant to the splash/spillage of Nitocote EN901 is a solvent free, highly crosslinked, high build epoxy-novolac-based coating. Nitocote EN901 is a two- part material and can be applied by brush, roller or airless spray. Nitocote EN901 is grey in colour. It is formulated to be applied in one or two coats to achieve a minimum total-dry- Bleach (Sodium hypochlorite) KeroseneBoric Acid * film thickness of 500 microns. Higher thickness can be Chemical and abrasion resistant lining
The chemical and abrasion resistant coating shall be Nitocote EN901, a high build, two-pack epoxy-novolac system specially designed to provide a tough and impermeable high The local Fosroc office should be consulted for resistance to specific chemicals and conditions or when long term Re-coating
To re-coat, it is imperative that the second coat be applied Preparation of concrete surfaces
within the specified over-coating time.
All surfaces, which are to receive the lining, must be at least 28 Use of glass fibre reinforcement
days old and have a moisture content of less than 5%. These surfaces shall be dry, sound and free form debris and loose Nitocote EN901 may be used in conjunction with glass fibre material. The substrate must be free from contamination such cloth to increase the thickness of the system or, where as oil, grease, wax, dirt or any other form of foreign matter necessary, bridge fine cracks in the substrate. The cloth should be laid directly on the first coat whilst wet and should be pressed in and smoothed out with a split washer roller. A All blow holes and imperfections should be filled with second coat should then be applied within the specified over- Preparation of steel surfaces
Use of Fosroc Anti-slip grains
All surfaces should be grit blasted to meet the requirements of Nitocote EN901 can be used in conjunction with Fosroc Antislip Grains*† to provide a heavy-duty slip-resistant flooring system.
The lining work should be programmed so that newly cleaned The first coat will be applied as described above with a steel is coated as soon as possible before the formation of minimum film thickness of 200 microns. The base coat should now be dressed with the chosen Fosroc Antislip Grains.
The recommended procedure is to completely blind the base Nitocote EN901 is designed to be used without primer.
coat i.e. apply excess dressing aggregate to completely However, if the condition of the concrete substrate requires When the base coat has reached initial cure, the excess Antislip Grains should be vacuum-cleaned from the surface.
It is imperative that the resin be thoroughly mixed with the The top coat can then be applied. Care should be taken to hardener in the exact ratios to ensure optimum performance.
ensure that a continuous film is achieved and the surface is Therefore, the entire contents of the hardener can should be added to the base container and mixed until a uniform colour Cleaning
and consistency are obtained, taking particular care to scrape the sides and bottom of the container. It is recommended that Nitocote EN901 should be removed from tools and equipment mechanical mixing be employed using a Jiffy mixer on a slow with Nitoflor Sol* immediately after use. Cured material can Application
Once mixed, Nitocote EN901 should be immediately applied Substrate, ambient and product temperature must remain to the prepared surface ensuring a continuous coating of above 15°C during application and curing. Minimum material/container temperature for spray application is 20°C. Avoid moisture contamination.
Stiff nylon brush or short nap roller is recommended for such application. Faster rate of application is possible using airless Nitoflor EN901should not be applied on to surfaces known to, or likely to suffer from, rising dampness, potential osmosis problems or have a relative humidity greater than 75% as measured in accordance with BS 8203 Appendix Application should not be undertaken if the temperature is Air conditioned storage at high ambient temperatures is below 5°C, or is 5°C and falling, nor when the prevailing Nitocote EN901 may not be colour stable when in contact with some chemicals or direct sunlight. The colour change Health and safety
will not affect the performance of the protective system Nitocote EN901 and Nitoflor Sol should not come in contact with skin and eyes, or be swallowed. Ensure adequate ventilation and avoid inhalation of vapour. If working in confined areas, then suitable respiratory equipment must be worn.
Fosroc offers a comprehensive technical support service to Some people are sensitive to resins and solvents. Wear specifiers, end users and contractors. It is also able to offer suitable protective clothing, gloves and eye/face protection.
on-site technical assistance, an AutoCAD facility and Barrier creams provide additional skin protection. Should dedicated specification assistance in locations all over the accidental skin contact occur, remove immediately with a resin-removing cream, followed by soap and water. Do not
use solvent. In case of contact with eyes, rinse immediately with plenty of clean water and seek medical advice. If swallowed, seek medical attention immediately - do not
4 litre packs
1 & 4 litre packs
5 and 20 litre cans
Nitoflor Sol is flammable. Keep away from sources of ignition.
Coverage
No smoking. In the event of fire, extinguish with CO or foam.
0.5 litre /m2 @ 500 microns
Do not use a water jet.
5.5 - 6.5 m2 per litre
Flash points
Note: The coverage figure is theoretical - due to wastage
factors and the variety and nature of substrates, practical coverage figures may be substantially For further information, refer to the Product Material Safety When stored in dry air conditioned stores at temperatures between 15-30°C, in the original, unopened containers Nitocote EN901 will have a shelf life of 12 months.
If stored at high temperatures the shelf life will be reduced.
Fosroc manufactures a wide range of complementary Fosroc additionally offers a comprehensive package of products specifically designed for the repair and refurbishment of damaged concrete. Fosroc’s ‘Systematic Approach’ to concrete repair features the following : anti-carbonation/anti-chloride protective coatings For further information on any of the above, please consult your local Fosroc office - as below.
® Denotes the trademark of Fosroc International Limited
Important note :
Fosroc products are guaranteed against defective materials and manufacture and are sold subject
to its standard terms and conditions of sale, copies of which may be obtained on request. Whilst Fosroc endeavours to ensure that any advice, recommendation specification or information it may give is accurate and correct, it cannot, because it has no direct or continuous control over where or how its products are applied, accept any liability either directly or indirectly arising from the use of its products whether or not in accordance with any advice, specification, recommendation Fosroc Chemicals (India) Pvt. Ltd.
Head Office

telephone fax
++91 80-22240018/120 ++91 80-22233474 [email protected] Regional Offices
Bangalore
Ahmedabad : (079) 26762799 Ankleshwar :(02646) 220704/224687 Bhubaneshwar : (0674) 2521176 Chennai (044) 24899949/24853383Chandigarh : (0172) 2639360 Cochin : (0484) 2356668 Coimbatore : (0422) 2472966 Goa : (0832) 2542465 Guwahati (0361) 2548793Hyderabad : (040) 27662324/27662425 Hubli (0836) 3402597 Indore : (0731) 504339/5061477 Jaipur : (0141) 2235349 Lucknow :(0522) Nagercoil (04652) 2224849 Mangalore: (0824) 22272234 Visakhapatnam : (0891) 2564850 INDIA/2004/0771/A

Source: http://www.forsterindustrial.co.uk/files/Products/Fosroc/Protective%20Coatings/Fosroc_Nitocote_EN901.pdf

Mifepristone_ecfactsheet.pmd

What You Need to Know The Difference Between Medical Abortion and Emergency Contraceptive Pills There is considerable confusion, even among experiencedoral contraceptives taken in increased doses also may behealth care providers, about the difference betweenused as ECPs. Mifepristone has also been shown to bemedical abortion (also known as “medication abortion”)effective for emergency

Microsoft word - wchs enrollment front page.doc

Clark-Pleasant Community School Corporation Permission to Administer Medication and First Aid to Student School Year: 2009-10 This form is valid for one school year and must be renewed yearly. Student Name Home Phone Grade Student health alerts, medical conditions, or allergies: I am the parent/guardian of the above-named child whose date of birth is / / . I