Asnc2008 poster session ii - comparison with other modalities
POSTER SESSION II Friday, September 12, 2008, 9:30 a.m. – 11:00 a.m. Comparison with Other Modalities
septum and the apex in normal eye analysis of grayscale. The interventric-
BETA BLOCKER UTILIZATION AND SAFETY IN AN OUTPATIENT
ular septum enhanced the most followed by the lateral wall, posterior wall,
CARDIAC COMPUTED TOMOGRAPHIC ANGIOGRAPHY ENVIRONMENT
inferior wall, anterior wall, and the apex (as a reference, the CT number for
D Gopalakrishnan,1 D Abner,2 A Gopal,2 N Ahmadi,2 RS Pal,2 MJ Budoff2
a non-enhanced tissue: 40 HU). In 25 individuals, the HU of dark areas in
1The Heart Hospital Baylor Plano, Plano, TX, 2Los Angeles Biomedical
the myocardium by eye analysis was very low (6.5 Ϯ 35.4 mean HU)
Research Institute at Harbor UCLA Medical Center, Torrance, CA
showing a wide range of hypoenhancement. Background: An optimal heart rate control is mandatory with the current Conclusion: “Normal” grayscale analysis by the human eye appeared to
64-slice scanners to prevent motion artifacts during cardiac computed
correctly identify the normally enhanced myocardium with wide spectrum
tomographic angiography (CTA). Depending on the practitioner’s comfort
of contrast enhancement differences from apex to septum. Additionally, the
level, beta blocker (BB) administration is done either exclusively by the
dark areas based on eye analysis clearly reflected significantly lower HU
aggressive rapid intravenous (IV) administration while on the table (IV
metoprolol 5 mg every 1 minute up to a maximum dose of 50 mg) or by the conservative oral outpatient 3-day preparation with metoprolol or atenolol. Concerns regarding their safety have resulted in some practices considering the purchase of more expensive scanners with increased temporal resolution to eliminate the use of such heart rate slowing medications during CTA. This study was done to evaluate the feasibility and safety of heart rate slowing medications in an outpatient CTA setting. Methods: Fifty-one consecutive patients (age 56 ϩ 13 years, 71% males) with an intermediate likelihood of coronary artery disease who underwent CTA were studied. The heart rate was initially assessed 3 days before the procedure and the patients were started on BB, either metoprolol or atenolol once a day. On the day of testing, the heart rate was measured again and if the HR was Ͼ 65, IV metoprolol was used at doses of 5-10 mg every 3 minutes up to a dose of 40 mg. As needed, IV verapamil up to 10 mg was also used to assist the BB. Results: Seventy-one percent of the individuals received a daily outpatient BB based on the initial heart rate assessment. Twenty-nine percent required IV BB on the day of CTA and only one required additional IV verapamil. Receiving outpatient BB reduced the use of IV BB on the day of CTA to slow the heart rate by 69%. In those who already received outpatient BB, only 31% required IV medications to further assist versus 27% with optimal initial heart rate who did not receive prior oral BB (P Ͼ 0.9). Heart rate at the time of acquisition was 59.7 ϩ 5.4 bpm. The images were acquired with a 64-slice scanner and were of good quality without significant motion artifacts. There were no adverse affects while the patients were in the lab or after going home, and these medications were well tolerated. Conclusion: Medications like BB and calcium channel blockers can be safely used in an outpatient setting and significantly reduce the IV BB to slow heart
rate on the day of CTA. During CTA, contrast-related reactions are more likely
PROSPECTIVE TRIGGERING WITH DUAL SOURCE CARDIAC CT:
to happen than those caused by such heart rate slowing medications.
INITIAL CLINICAL EXPERIENCER Blankstein, AB Shah, RA Pale, S Abbara, W Mamuya, U Hoffmann,
Massachusetts General Hostpital, Boston, MA
COMPARISON TO THE ACTUAL CONTRAST ENHANCEMENT IN
Background: Prospectively triggered (PT) cardiac CT, whereby radiation is
only administered at a predefined phase of the cardiac cycle, has been shown
N Ahmadi, EP Young, RS Pal, K Nasir, V Gabrielian, SS Mao,
to substantially reduce patient radiation dose. Recent preliminary study
showed the feasibility of this technique when a single source scanner was
Los Angeles Biomedical Research Institute at Harbor UCLA Medical
used and all patients were treated with beta-blocker medications. The aim of
our study was to assess the use of this technique in a clinical patient
Background: Given the limitations of human eye for grayscales, only
population using the Dual Source Cardiac CT (DSCT; temporal resolution
myocardial lesions that are infarcted or those areas replaced by calcium or
83msec) when beta blockers were not routinely administered.
fat will be promptly recognized from normal grayscale analysis in cardiac
Methods: Among 200 consecutive patients (pts) referred for a clinical DSCT
computed tomographic angiography (CTA). On the other hand, subtle
exam, prospective triggering was utilized in 20 pts. kV (range 100-140, average
changes in the “normal” grayscale may be overlooked. We sought to
116) and mAs (average 119) were chosen for each patient based on physician
analyze the pattern of contrast enhancement of the walls of the left
assessment of body habitus. Beta blockers were not administered (except for 1
ventricular (LV) chamber in a normally appearing LV chamber.
pt). Effective radiation dose was calculated by multiplying the dose-length
Methods: CTA images from 75 individuals (age 63 Ϯ 13 years, 73% males)
product (DLP) times a conversion factor (k ϭ 0.017 mSv/mGy/cm). All data
were analyzed by an experienced reader using a GE Advantage Workstation
related to scan acquisition parameters was collected prospectively. Per-patient
(AW 4.3). The maximum, mean, and the SD (standard deviation or the
analysis of non-evaluable segments was determined based on clinical readings.
noise) Hounsfield Units (HU) were measured using the ROI (region of
Results: Of the 20 PT scans performed, (mean age 42, mean BMI 29.3, 70%
interest) tool in these LV chambers of relatively normal appearing gray-
male), 13 pts were referred for coronary evaluation, 6 were referred for
evaluation of coronary arteries and aortic disease (larger coverage), and 1 pt was
Results: There were differences in the pattern of contrast enhancement of
referred for evaluation of a cardiac mass. The average heart rate was 66 bpm.
the LV chamber walls that was close to a 30% difference between the
All pts were in normal sinus rhythm, and 20% had either PACs or partial-
volume correction (PVC) during the acquisition. The average radiation dose for
all 20 exams was 3.5 mSv (range 1.3 - 6.7) As expected, lower effective dose
DETECTION OF CORONARY ARTERY DISEASE BY FREE-BREATHING,
was achieved with lower kV and smaller coverage. When excluding the 6
WHOLE HEART CORONARY MAGNETIC RESONANCE ANGIOGRAPHY:
studies which had a larger coverage, the average dose was 3.2 mSv. Of these,
those which used 100kV resulted in an average dose of 1.5mSv. Twenty percent
T Kunimasa, N Matsumoto, Y Nakano, Y Suzuki, S Yoda, T Kanai,
(4/20) of pts had at least one non-evaluable segment. The reasons for
non-evaluable parts included ectopy resulting in slab artifacts (2 pts), calcium (1
Nihon University School of Medicine, Tokyo, Japan Background: Free-breathing, whole heart coronary magnetic resonance
pt) and presence of intra coronary stent (1pt).
angiography (MRA) has gained a great attention as a totally noninvasive
Conclusions: Even in the absence of beta-blockers, use of prospective
diagnostic modality for the detection of coronary artery disease. We
triggering DSCT is feasible and results in a significant reduction of radiation
examined the accuracy of coronary MRA to identify the presence or absence
dose. Use of beta-blockers to decrease ectopy may reduce the number of
of coronary artery stenosis in comparison with conventional coronary
angiography. Methods: Free-breathing, whole heart coronary MRA with diaphragm drift
correction software was performed in 39 consecutive patients undergoing
ATHEROSCLEROTIC PLAQUE MORPHOLOGY ASSESSMENT
conventional coronary angiography. A total of 156 coronary arteries and
ACCORDING TO BURDEN OF CORONARY ARTERY DISEASE
312 coronary artery segments were analyzed.
IN PATIENTS WITH TYPE 2 DIABETES MELLITUS BY NON-
Results: In the vessel-based analysis, the sensitivity to detect coronary
stenosis Ն 50% was 80% and the specificity to define luminal narrowing Ͻ
UN Ibebuogu,1 K Nasir,2 N Ahmadi,3 A Gopal,3 D Goodwin,3 MJ Budoff3
50% was 97%. The accuracy, positive predictive value, and the negative
1Medical College of Georgia, Augusta, GA, 2Massachusetts General
predictive value were 92%, 93%, and 92%, respectively.
Hospital, Boston, MA, 3Los Angeles Biomedical Research Institute at
Conclusions: Free-breathing, whole heart coronary MRA that provides
diaphragm drift correction software yields excellent diagnostic accuracy to
Background: Patients with diabetes mellitus (DM) have a higher risk of
detect significant coronary artery disease and has potential to become the
coronary artery disease (CAD) and are likely to have a higher underlying
routine diagnostic modality for patients with suspected coronary artery
atherosclerotic burden. However the atherosclerotic plaque composition in
these patients is not studied. In this study we evaluated the plaque burden,morphology, and distribution in type 2 DM patients using multi-detector
computed tomography angiography (MDCTA).
EVALUATION OF ISCHEMIC MYOCARDIAL STUNNING FOLLOWING
Methods: The study population consisted of 40 symptomatic diabetic subjects
ADENOSINE VASODILATOR STRESS USING CARDIAC MAGNETIC
(63 Ϯ 10 years, 55% men), who underwent contrast-enhanced MDCTA.
RESONANCE IMAGINGL Bakhos, TA Holly, E Wu, DC Lee
Enrolled patients had an intermediate pre-test probability of obstructive CAD. Results: A majority of individuals (n ϭ 33, 83%) had at least one segment with Background: Several studies have reported myocardial stunning in up to
any plaque; 69% of diabetic had detectable coronary artery calcification (CAC)
30% of patients undergoing adenosine SPECT imaging. However, in
and 36% had CAC Ն 400. Among individuals with any plaque the mean
patients with significant perfusion defects, the edge-detection algorithm that
number of segments involved were 5.7 Ϯ 3.0 segments; the respective mean
gated SPECT relies on may fail to properly assess wall motion. Therefore,
number of segments with exclusively non-calcified, calcified and mixed plaques
the purpose of this study was to evaluate the incidence of myocardial
were 1 Ϯ 1, 2.7 Ϯ 2.4, and 2 Ϯ 2 segments, respectively. Among those with
stunning following adenosine stress by cardiac magnetic resonance imaging
any plaque, the overall proportion of segments that had noncalcified, calcified,
(CMR), a modality in which functional analysis is independent of perfusion.
and mixed atherosclerotic plaques were 25%, 44%, and 31%, respectively
Methods: Thirty-three patients undergoing adenosine vasodilated CMR
In our study, 12 patients (30%) had at least one coronary segment
perfusion imaging were retrospectively identified. Basal, mid, and apical
with significant stenosis (luminal narrowing Ն 50%). Type 2 DM patients in
short axis cines were acquired before and immediately after adenosine
our study with significant stenosis were more likely to have plaque composition,
infusion. Ejection fraction (EF) was measured blindly using CAAS-MRV
that was mixed in nature (39% vs. 28%) and less likely to be exclusively noncalcified plaque alone (17% vs. 26%) when compared to those without significant stenosis. On the other hand, no difference was observed in the respective proportion of exclusively calcified plaque (44% vs. 46%). Conclusions: Our study demonstrates a high burden of CAD in patients with diabetes. Majority of atherosclerotic plaque in these patients had calcification, however among patients with significant CAD, mixed plaque composition was more commonly observed. The prognostic value of these different atherosclerotic plaque morphologies on MDCT in high risk DM patients need to be assessed in larger prospective studies.
(PieMedical, Maastricht, The Netherlands). First-pass perfusion imaging
mA, and 3 mm slice thickness. The parameter of MDCT was 140 kVp, 430
was performed at matched slice positions and blindly analyzed visually
MA, 350 ms/per rotation and 2.5 mm in thickness. The calcium score were
(0-normal to 3-severe defect) on a 16-segment model. Sum difference score
measured with the Aquarius workstation (Terarecon, Inc). Each calcific foci
(SDS) was the stress defect score minus rest defect score (maximum 48).
was measured. The Chi-square test (X2) was completed to test the difference
Results: The mean EF prior to adenosine infusion was 44.8%. The mean EF
in sensitivity to detect small and low density calcium foci.
following adenosine infusion was 46.0%. As seen in Figure 1, pre- and
Results: The foci number that can be detected and scored was 58/66 and
post-adenosine EF are highly correlated with a slope of 1.0 (95% confidence
40/66 in the in-vivo group and 46/57 and 35/57 in the in-vitro study using
interval 0.90 - 1.05). Severe reversible perfusion defects (SDS Ն 5) were
GE64 and EBT respectively (PϽ0.05).
seen in 15/32 (47%) of patients. In these patients, mean pre- and post-
Conclusions: There was a significant increase in the sensitivity to detect
adenosine EF were 44.7% and 46.8% respectively.
small or low density calcium foci with 64-MDCT in both patients and
Conclusion: Myocardial stunning was not seen in patients undergoing
adenosine vasodilated CMR perfusion imaging, even in the presence ofsignificant reversible perfusion defects. The apparent fall in EF reported in
nuclear single-photon emission computed tomography studies may be due
ROLE OF CORONARY FLOW RESERVE DURING HIGH RESOLUTION
to suboptimal edge detection rather than myocardial stunning due to
B-MODE ULTRASOUND IN THE FUNCTIONAL ASSESSMENT OF
CORONARY ARTERY STENOSIS: COMPARISON WITH GATEDSPECT
M Damiano, L Ferrara, P Gallo, C De Simone, A D’Errico,
RELATIONSHIP BETWEEN CORONARY STENOSIS BY MULTI-SLICE
CT ANGIOGRAPHY AND ISCHEMIA BY TC-99M PERFUSION SPECT
T Chua,1 S Tan,1 J Huang,2 F Keng,1 R Tan,1 F Cheah2
Background: To estimate the value of coronary flow reserve (CFR), as
1National Heart Centre, Singapore, Singapore, 2Singapore General
measured by transthoracic Doppler echocardiography, for functional assess-
ment of stenosis severity in comparison with exercise gated single-photon
Background: Multislice computed tomography (MSCT) shows great prom-
emission computed tomography (SPECT).
ise for the detection of coronary artery disease (CAD), but there is limited
Methods: We studied 142 patients suspected of having coronary artery
data comparing its accuracy with established methods such as Tc-99m
disease. The flow rate in the distal left anterior descending (LAD) coronary
perfusion (single-photon emission computed tomography (SPECT).
artery was measured by echocardiography both at rest and during intrave-
Methods: We compared the results of 16-Slice MSCT angiography using a
nous infusion of dipyridamole. CFR was calculated as the ratio of hyper-
Siemens scanner with stress-rest Tc-99m Sestamibi Gated SPECT (dual
emic to basal peak diastolic flow velocities. The CFR measurements by
head gamma camera, Philips) in 59 patients who underwent both procedures
ultrasonography were compared with the results of gated-SPECT. All
within 6 months at our hospital with no intervening revascularization or
patients underwent coronary angiography as control.
cardiac events. SPECT was performed with symptom-limited exercise in 52
Results: Complete Doppler ultrasound data were acquired for 136 of 142
patients and vasodilator stress in 7 patients for the diagnosis of CAD or
study patients. Of these 136 patients, SPECT confirmed reversible perfusion
detection of ischemia. Results were defined as normal or abnormal based on
defects in the LAD territories in 82 patients (group A). Fifty-four patients
the presence or absence of ischemia. CAD detected by MSCT was graded
had normal perfusion in the LAD territories (group B). Peak CFR (mean
as absent, mild (0-40% diameter stenosis), moderate (40-70%), severe
value Ϯ SD) were 1.6 Ϯ 0.5 in group A and 2.4 Ϯ 0.7, respectively (p Ͻ
0.001). CFR Ͻ 2.0 predicted reversible perfusion defects, with a sensitivity
Results: All patients with total occlusions had ischemic SPECT studies,
and specificity of 88% and 84%, respectively.
compared to 15/20 (75%) patients with severe or total occlusions, 17/28
Conclusions: Noninvasive measurement of CFR by transthoracic Doppler
(61%) patients with moderate or worse stenosis, 19/60 (32%) patients with
ultrasonography provides a functional estimation of LAD stenosis severity
any grade of CAD and 4/19 (21%) patients with no detectable CAD by
MSCT (p ϭ 0.008). Of 36 patients with normal SPECT studies, 21 (58%)had evidence of atherosclerosis by CTA, though only 5/36 (14%) had severe
disease. Of 23 patients with abnormal SPECT studies, 19/23 (83%) had
SIGNIFICANT DIFFERENCES IN LEFT VENTRICULAR VOLUMES
evidence of CAD, with 15/23 (65%) assessed as severe or occluded by
AND EF BETWEEN GSPECT AND ECHOCARDIOGRAPHY AND
CTA. One-quarter of patients with stenosis assessed as severe by CTA had
A Hovland,1 H Bjørnstad,1 UH Staub,1 J Prytz,1 A Støylen,2 H Vik-Mo2
Conclusions: There is a stepwise relationship between SPECT findings and
1Nordland Hospital, Bodo, Norway, 2St Olav Hospital, Trondheim,
MSCT, with an increasing prevalence of ischemia as the degree of stenosis
increases. However, 25% of patients with stenosis assessed as severe by
Background: Left ventricular ejection fraction (EF) is a powerful predictor
CTA had normal SPECT studies, suggesting the absence of ischemia despite
of prognosis in coronary artery disease and is often estimated by echocar-
diography or nuclear imaging. The purpose of the current study was tomeasure end diastolic and end systolic volumes and hence EF for echocar-
diography compared with different gated single-photon emission computed
COMPARISON OF EBT AND 64 MDCT TO DETECT SMALL OR
tomography (GSPECT) software and to measure interrater differences using
LOW-DENSITY CALCIUM FOCI: AN IN-VIVO AND IN-VITRO
Methods: Eighty-four patients scheduled for nuclear imaging due to known
MJ Budoff,1 SS Mao,2 N Ahmadi,1 F Flores,1 H Wu,1 N Neal,1 N Petal1
or suspected coronary artery disease underwent GSPECT (patients with
1Los Angeles Biomedical Research Institute, Torrance, CA, 2Los Angeles
atrial fibrillation or left bundle branch block were excluded). We used a
Biomedical Research Institute, Carson, CA
1-day protocol GSPECT with 99mTc-tetrofosmin, using 8 frames/cardiac
Background: The aim of this study was to estimate the sensitivity to detect
cycle during rest images. GSPECT images were processed by two raters
small or low density calcium foci with Electron Beam Tomography (EBT)
who estimated left ventricular volumes and EF using the Cedar-Sinai
and 64 multidetector computed tomography (MDCT) (GE 64).
quantitative gated-SPECT (QGS), Emory Cardiac Toolbox (ECTB) and
Methods: The in-vivo group included 66 single coronary arteries with solid
4D-MSPECT of the University of Michigan. Echocardiographic volumes
calcium foci of Ͻ10 Agatston score (AS), selected from 93 patients who
were measured by biplane Simpson‘s method. Measures are means Ϯ SD.
underwent coronary calcium scanning (CAC) with both EBT and MDCT on
Differences were compared with t-tests. Interrater differences were calcu-
the same day. All foci can be scored by either scanner or both EBT or
lated as mean difference (95% limits of agreement).
MDCT. The in-vitro study included a cork chest phantom with dog heart, 57
Results: The 84 patients were 62.1 years Ϯ 8.9, 35% were women, and 26%
small (Ͻ6.6-18.9 mm3 with 200 mg/cc) or low density foci (14.8-157.8
previously had myocardial infarction. Echocardiographic end diastolic
mm3, 150mg/cc) were inserted into a coronary artery and sealed with wax.
volume was 90.4 ml Ϯ 28.1, end systolic volume 32.1 ml Ϯ 18.7, and EF
The technique parameters of EBT (GE Imatron) were 100 ms, 130kVp, 630
65.8% Ϯ 10.5. GSPECT volumes and EF are shown in Table 1.
Interrater mean difference in end diastolic volumes by QGS was 0.92
very good with no documented hard cardiac events to date. The findings of
(-12.6-14.5), ECT -2.9 (-31.9-26.2), pϭ0.013 compared to QGS, 4D-
severely obstructive CAD in 5 patients with CAC of 0 preclude the use of
MSPECT -0.52 (-10.6-9.6), pϭ0.041. Interrater difference in end systolic
CAC for excluding CAD, particularly in symptomatic younger patients.
volumes by QGS was 1.5 (-5.7-8.7), ECT -0.45 (-9.1-8.1) pϭ0.004,4D-MSPECT 0.32 (-7.5-8.2) pϭ0.046.The interrater mean difference in EF
for QGS was 1.1( -5.3-7.5), mean difference for ECT was 0.05 and 95%
( -9.4.9.5) ,pϭ 0.062 compared to QGS and mean interrater difference was
MYOCARDIAL PERFUSION IMAGING AND DOBUTAMINE
0.69 for 4D-MSPECT and 95% limits of agreement were -8.59-9.97
STRESS ECHOCARDIOGRAPHY IN THE DETECTION OF
CORONARY ARTERY DISEASE IN HYPERTENSIVE PATIENTS
Conclusions: Ejection fraction and left ventricular volumes calculated by
N Sultana,1 I Nisa,1 S Banarjee,2 AH Jehan3
different software programs in gated SPECT differ significantly from those
1Institute of Nuclear Medicine and Ultrasound, Dhaka, Bangladesh,
obtained by biplane echocardiography. There are significant interrater
2BSM Medical university, Dhaka, Bangladesh, 3Center for Nuclear
differences in end diastolic and end systolic volumes with different
software. The discerning clinician should keep in mind that volumes and EF
Background: Simultaneous dobutamine stress myocardial perfusion imag-
reported by a GSPECT study may differ between raters and from echocar-
ing and dobutamine stress echocardiography for the evaluation of the
presence and extent of coronary artery disease (CAD) are assessed for ahead-to-head comparison regarding the diagnostic accuracy of the two tests
Table 1. Volumes and EF, *p Ͻ 0.05, **p Ͻ 0.001 compared to echocardiography
in hypertensive group of patients. The aim of this study is to compare the
End diastolic End systolic
sensitivity and specificity of these two imaging modalities, for the detection
Software volume, ml volume, ml Methods: This prospective observational study was performed at the
Institute of Nuclear Medicine & Ultrasound in collaboration with the
cardiology department of BSM Medical University, Dhaka from January2006 to July 2007. A total of 80 patients (male 82% and female 18%, mean
age 55.0 Ϯ 1.02 years, range 31-68 years) are included in this study and
VALUE OF SAME-SESSION CORONARY ARTERY CALCIUM (CAC)
informed about the necessity, risk, and benefit of these two tests. Informed
SCORING IN THE SETTING OF STRESS MYOCARDIAL PERFUSION
consent was obtained. All patients underwent simultaneous dobutamine
IMAGING (MPI) USING CT-BASED ATTENUATION CORRECTION
stress echocardiography (DSE) followed by dobutamine stress myocardial
perfusion imaging (MPI) in single day stress-rest protocol with Tc 99m
tetrofosmin. Coronary angiogram was performed in all patients within one
month after imaging studies (significant stenosis was Ͼ 50%). Background: Findings of a zero or very low coronary artery calcium score Results: The overall sensitivity, specificity, and predictive accuracy of
(CAC) or a normal or low-risk myocardial perfusion single-photon emission
dobutamine stress myocardial perfusion imaging for the detection of
computed tomography (SPECT) study using computed tomography-based
coronary artery disease were 97%, 62.5%, and 90%, respectively. Positive
attenuation correction (CTAC), have excellent negative predictive value for
predictive values were 91.2% and negative predictive value was 83.3%. The
short- and intermediate-term hard and soft coronary events. CAC is
overall sensitivity, specificity, and predictive accuracy of dobutamine stress
sensitive for underlying coronary artery disease (CAD), but not specific for
echocardiography for the detection of coronary artery disease were 92%,
degree of luminal stenosis, whereas SPECT myocardial perfusion imaging
75%, and 88.7%, respectively. Positive predictive values were 93.7%, while
(MPI) displays greater specificity for flow-limiting CAD and positive
negative predictive value was 70.6%. Dobutamine stress MPI showed
predictive value for short-term events. Data evaluating the potential syner-
higher sensitivity than DSE (p Ͼ 0.05), but specificity lower than DSE (P Ͼ
gism between these two techniques are limited. We examined the correla-
0.05), that does not rich the level significance.
tion between degree of CAC and MPI abnormalities using CTAC and
Conclusions: In our study, both non-invasive methods for the detection of
assessed concordance in patients further evaluated with angiography.
CAD showed a good diagnostic accuracy. Nevertheless the dobutamine
Methods: A total of 250 subjects with no history of CAD referred for stress
stress myocardial perfusion imaging showed higher sensitivity in compar-
MPI were studied. Imaging was performed using Siemens SYMBIA-T6
ison with DSE in this specific group of patients.
SPECT-CT imaging systems (Siemens Medical Solutions, Hoffman Estates,IL) and a stress Tc-99 sestamibi protocol. Separate breathhold CT acquisi-
tions were acquired for CTAC and CAC. SPECT images were reconstructed
NON-INVASIVE STRESS TESTING OF MYOCARDIAL PERFUSION
for attenuation correction (including scatter correction and resolution
DEFECTS: HEAD-TO-HEAD COMPARISON OF THALLIUM-201
recovery) using manufacturers’ software without modification. CAC was
tabulated by vessel using a 13-segment coronary artery model and corre-
GM Vincenti,1 R Nkoulou,1 J Vallee,1 G Ambrosio,2 F Mach,1 O Ratib,1
lated with perfusion defects scored for severity, i.e. summed stress and
difference scores (SSS, SDS), and extent in each coronary distribution using
1Geneva University Hospital, Geneva, Switzerland, 2Perugia University
a standard 17-segment model. Results were analyzed for concordance and
further correlated with subsequent angiography in those patients referred
Background: To evaluate the diagnostic value of magnetic resonance
with a positive SPECT MPI study. Clinical outcome was based on review
perfusion imaging in the assessment of hemodynamically obstructive
coronary artery disease (CAD) in a head-to-head comparison with thallium-
Results: Of 250 subjects (51% male, 35% diabetic, 65% symptomatic),
201 (201TI) single-photon emission compute tomography (SPECT) as
CAC of 0, 1-10, 11-99, 100-399, Ն 400 were found in 100, 16, 52, 32 and
55 subjects, with CAC of Ͼ100 in 56% of normal MPI. Twenty-eight
Methods: Eighteen patients (mean age 61 Ϯ 5 years, 14 men, 4 women)
percent of all cases had CAC of Ͻ10 with normal MPI. Patients’ age ranged
with a history of angina pectoris were studied with 201TI-SPECT and fast
from 36 to 84 years, with a mean age of 55 years. Forty-eight patients had
gradient-echo (GRE) magnetic resonance imaging (MRI) of myocardial
subsequent coronary angiography. Higher SSS and SDS correlated with
perfusion during dipyridamole-induced vasomotor stress. Within 5 days of
angiographic disease severity across all CAC score ranges. Discordant
201TI-SPECT, GRE-MRI perfusion imaging was performed with the same
angiographic findings were present in 5 patients, 3 with typical angina
protocol as 201TI-SPECT. Images for both scans were obtained in oblique
symptoms, with CAC scores of 0, of whom 4 were under 50 years old. All
horizontal, vertical long axis and short axis planes. Myocardial segments
patients classified as normal/low risk were alive per CareWeb at 7 to 17
were assessed visually and myocardial perfusion was graded on a semi-
quantitative 5-point scoring system (0 ϭ normal, 1 ϭ mildly reduced
Conclusions: In patients with normal MPI, potentially valuable additional
perfusion, 2 ϭ moderately reduced perfusion, 3 ϭ severely reduced
information regarding underlying subclinical CAD was found in 58% with
perfusion, and 4 ϭ nearly absent perfusion) to derive the summed stress
CAC imaging, however, the intermediate outcome in this group remains
score (SSS), summed rest score (SRS) and summed difference score (SDS).
In all patients coronary angiography was performed to evaluate CAD
clinical practice, its clinical impact on health care resource utilization needs
to be better understood. We sought to determine the clinical impact of CTA
Results: Seven out of 18 patients studied had a history of previous
on ICA referrals, CTA accuracy, and CTA normalcy rate.
myocardial infarction. 201TI-SPECT determined myocardial ischemia (ab-
Methods: To determine the ‘impact of CTA’, 7,017 consecutive patients
normal SSS Ͼ 4) during dipyridamole stimulation was found in the regional
undergoing ICA prior to (n ϭ 3,538) and after (n ϭ 3,479) implementing a
myocardial territories supplied by the LAD (n ϭ 6), LCX (n ϭ 5), and RCA
cardiac CT program were reviewed. For the CTA ‘accuracy’, we evaluated
(n ϭ 7) with a SSS of 22 Ϯ 11, SRS of 14 Ϯ 10, and SDS of 8 Ϯ 4. By
consecutive CTA patients who underwent ICA. For ‘normalcy rate’, we
201TI-SPECT, the sensitivity to detect hypoperfused segments was 61%
identified 201 patients with a low pre-test probability for obstructive CAD
(11/18) with the GRE-MRI analysis. The difference in the detection of
stress-induced perfusion defects (n ϭ 7) between 201TI-SPECT and
Results: With the implementation of a cardiac CT program, the frequency
GRE-MRI reached statistical significance (pϽ0.001 by chi2-test). The
of ‘normal’ ICA decreased from 31.5% (1,114/3,538 patients) to 26.8%
sensitivity, specifity, negative predictive and positive predictive value, and
(932/3,479 patients) (p Ͻ 0.001). Analysis of the 148 CTA patients that
accuracy for GRE-MRI analysis of myocardial perfusion in the detection of
underwent ICA showed CTA had excellent “per patient” sensitivity (99%),
flow-limiting epicardial coronary artery lesions, as defined as diameter
positive predictive value (92%), and negative predictive value (95%) for
stenosis Ͼ50%, were 72%, 100%, 54%, 100%, and 73%, respectively.
obstructive CAD. The positive likelihood and negative likelihood ratios
Conclusions: These preliminary results indicate a moderate diagnostic
were 11.9 and 0.06, respectively. Using thresholds of Ն50% diameter
accuracy of cardiac GRE-MRI perfusion imaging during dipyridamole-
stenoses, the ‘normalcy rate’ of CTA was 94%.
induced coronary flow increases in the detection of flow-limiting epicardial
Interpretation: The clinical implementation of CTA appears to positively
artery lesions. The concordance between 201TI-SPECT and cardiac GRE-
impact ICA by reducing the rate of normal ICA. As well, the high diagnostic
MRI imaging in the detection of stress-induced perfusion defects was
accuracy of CTA supports its role as a clinically useful tool.
relatively low, and 39% of 201TI-SPECT-determined perfusion defectswere not identified by cardiac GRE-MRI, which deserves further investi-
REPRODUCIBILITY OF EJECTION FRACTION ASSESSMENT BYCT-ANGIOGRAPHY
F Alqaisi, C Poopat, C Nelson, M Al-Mallah
COMPUTED TOMOGRAPHIC CORONARY ANGIOGRAPHY AND
FRAMINGHAM RISK FACTOR SCORES: FURTHER SUPPORT FOR
Introduction: Cardiac computed tomography (CTA) has emerged as a new
tool to assess left ventricular ejection fraction (LVEF). The accuracy of
BJW Chow,1 RS Beanlands,1 TD Ruddy,1 GA Wells,1 L Chen,1 Y Yam,1
multiphase CTA in the measurement of LVEF has been demonstrated in
comparison to other imaging modalities. However, the reproducibility of
1University of Ottawa Heart Institute, Ottawa, ON, Canada, 2Ottawa
CTA assessment of LVEF has not well been demonstrated. The aim of this
study is to assess the interobserver variability in the LVEF assessment by
Background: Framingham risk scores (FRS) are routinely used to identify
individuals who may benefit from aggressive risk factor modification but
Methods: Multiphase CTA (20 phases, 2.5 mm slice thickness) of 45
FRS does not account for genetic and environmental variables. Computed
patients were reprocessed for LVEF assessment by three investigators: an
tomographic coronary angiography (CTA) can non-invasively assess coro-
experienced computed tomography technologist with 3D imaging training,
nary atherosclerosis and is an ideal modality for the identification of
an inexperienced cardiology trainee, and a cardiologist with level-3 training
subclinical atherosclerosis. The objective of this study is to understand the
in CTA. The investigators were blinded to each others interpretations. All
relationship between FRS and coronary atherosclerosis as measured by
processing was done using the Vitrea Workstation from Vital Images
(Minneapolis, MN). Pearson’s correlation coefficients were calculated. Methods: Consecutive patients who underwent CTA were prospectively Results: The mean age was 57.6 Ϯ 10.4 years and 58% were males. There
enrolled and categorized according to FRS. Atherosclerotic calcific and
was excellent inter-observer correlation between the LVEF measurement by
the experienced technologist and the level 3 cardiologist. (r ϭ .92, p Ͻ
Results: In this study, 447 patients without a history of MI, DM and not on
.001). The median difference in the LVEF assessment was 3% (range 1-11).
statin therapy were categorized according to FRS. Coronary atherosclerosis
There was significant but less strong correlation between the LVEF
was present in 60.6% of patients. Of the 258 patients with very low FRS
assessment by the trainee and either the experienced technologist (rϭ0.78,
(calculated 10-year risk Յ5%), atherosclerotic plaque was visually present
pϽ.001) or the cardiologist (r ϭ 0.72, p Ͻ .001).
in 113 (43.8%). Furthermore, 9.1% of patients with high FRS had no
Conclusion: Assessment of LVEF by CTA was highly reproducible by an
evidence of atherosclerotic plaque. Although mean atherosclerotic plaque
experienced technologist and a level 3 cardiologist. Whether extensive
burden increased with the 10-year Framingham risk the correlation between
training improves the precision of LVEF by inexperienced trainee is yet to
FRS and plaque was fair (r ϭ 0.50; p Ͻ 0.001). Conclusions: Although FRS and other established clinical variables are predictive of coronary artery disease events, CTA provides evidence of
calcific and non-calcific coronary atherosclerosis in many patients with low-
THE IMPACT OF VOLUME AND READER EXPERIENCE ON THE
to intermediate-risk Framingham scores. Furthermore, a small minority of
DIAGNOSTIC ACCURACY OF CORONARY CT ANGIOGRAPHY
patients with high FRS have no evidence of atherosclerosis. Prospective
S Bhojraj, T Larson, K Abdul-Nour, MV Pantelic, M Al-Mallah
studies are required to determine the value of identifying subclinical
coronary atherosclerosis with CTA and modifying therapy based on these
Background: Sixty-four-slice computed tomography angiography (CTA)
has emerged as a powerful non-invasive tool to rule out coronary arterydisease (CAD). Most of the diagnostic accuracy data comes from high-
volume centers with highly experienced readers. The aim of this study is to
DIAGNOSTIC ACCURACY AND IMPACT OF COMPUTED
establish the diagnostic accuracy of CTA in a community setting, and to
TOMOGRAPHIC CORONARY ANGIOGRAPHY ON UTILIZATION
determine the impact of the reader experience on the positive and negative
predictive value (PPV, NPV) of CTA changes with reader experience.
BJW Chow,1 A Abraham,1 GA Wells,1 L Chen,1 TD Ruddy,1 Y Yam,1
Methods: We included 41 consecutive patients without known CAD who
had coronary CTA and coronary angiography within 90 days. The CTA and
1University of Ottawa Heart Institute, Ottawa, ON, Canada, 2Ottawa
angiograms were each evaluated using the standard American Heart
Association 16-segment model. A “by segment” analysis was performed
Background: Since computed tomographic coronary angiography (CTA)
using diagnostic coronary angiography as a gold standard.
has a high negative predictive value, it is a potential gatekeeper for invasive
Results: A total of 655 segments were analyzed. The sensitivity, specificity,
coronary angiography (ICA). Before CTA can be further accepted into
PPV, and NPV of CTA were 52%, 90%, 44% and 93% respectively.
Comparing the earlier cases to the later cases, there was an increase in the
widely used load-independent measure of DF, in a population with low
PPV (39% v. 50%) of CTA with no change in the NPV.
likelihood of cardiovascular disease. Conclusions: CTA retains a high NPV when performed outside of high Methods: This study evaluated 53 patients (55% male), mean age 57 years
volume centers, thus retaining its ability to significantly rule out coronary
(Ϯ 14), who had both GSPECT and TDI within 1 month and no significant
artery disease. Readers’ experience results in improving the specificity and
change in their clinical status between the two studies. Patients with
positive predictive value of the CTA.
coronary artery disease, hypertension, diabetes mellitus, atrial fibrillation,severe valvular disease, heart rate Ͼ100, or technically inadequate studies
Experience Sensitivity Specificity
were excluded. All echocardiograms were required to have normal ejection
fraction, normal wall motion, and no evidence of diastolic dysfunction by
standard TDI criteria, defined as a lateral wall E’ Ͼ10 cm/s for patientsbetween 45 and 54 years, Ͼ 9 cm/s for patients between 55 and 65 years
and Ͼ 8 cm/s for patients greater than 65 and an E/E’ ratio Ͻ 10. All
NORMAL LIMITS OF LEFT VENTRICULAR DIASTOLIC FILLING
GSPECT studies were required to have normal ejection fraction, normal
RATE BY GATED MYOCARDIAL PERFUSION SPECT: VALIDATION
wall motion, and no evidence of perfusion defects. LV PFR (end diastolic
volumes/second) by GSPECT was assessed using QGS software and
JA Gluck, D Desai, K Ngai, F Messineo, O Akinboboye
adjusted for heart rate (calculated PFR (cPFR)).
New York Hospital Medical Center of Queens, Flushing, NY
Results: Background: Impaired diastolic function (DF) precedes systolic dysfunc- tion in ischemic heart disease and is associated with systolic heart failure Average E’’ (EDV/s) ؎ SD Average E/E’’
and hypertrophic heart disease. Consequently, assessment of DF is animportant component of the evaluation of patients for cardiovascular
disease. Gated single-photon emission computed tomography myocardial
perfusion scintigraphy (GSPECT) can provide measurements of left ven-
tricular systolic and diastolic function. However, normal diastolic filling
parameters with this technique have not been fully validated. The objectiveof this study was to validate normal values for left ventricular peak filling
Conclusion: This study establishes age-specific normal values for diastolic
rate (PFR) by GSPECT with traditional tissue Doppler imaging (TDI), a
filling parameters by GSPECT validated with standard TDI parameters.
alergia al principio activo. Debe ser aplicado únicamente sobre zonas de piel intacta. Debeevitarse el contacto con los ojos o mucosas. Reacciones adversas: A la dosis terapéuticas recomendadas, la medicación es generalmente bien tolerada y noprovoca efectos colaterales ni secundarios. En personas hipersusceptibles, pueden llegar a presentarse trastornos leves como prurito,rubelación,
Demystifying Methemoglobinemia Demystifying Methemoglobinemia: A Clinically Pervasive Disorder with Ambiguous Symptoms Masking Prevalence, Morbidity, and Mortality. Dysfunctional hemoglobins are among the most confounding compromises to patient health and safety. Dyshemoglobins impede the blood's ability to deliver oxygen to the tissues. Methemoglobin (MetHb) is a dyshemoglobin that